Schindler elevator V-30 door machine instructions - Solutions - Huaqiang Electronic Network

Photocoupler

Inverter technical description:

Low-range machine, input, main voltage 230V+15%/--20% 47-63Hz

115V+15%/--20% 47-63Hz

Output, rated power, 380W (6-pole motor)

Power frequency, greater than >90%

Pulse frequency, ≥16KHz

Output voltage 3. 0---230V

Rated current, 2A

Rotating magnetic field frequency, 0---400Hz

Protection type, ZP20

High-end machine, input, main voltage 230V+15%/--20% 47-63Hz

115V+15%/--20% 47-63Hz

Output, rated power, 600W (6-pole motor)

Power frequency, greater than >90%

Pulse frequency, ≥16KHz

Output voltage 3. 0---230V

Rated current, 3.5A

Rotating magnetic field frequency, 0---400Hz

Protection type, ZP20

SSM Overview

display

On ¤ ¤

1 2 3

4 5 6

7 8 9

Esc 0 Enic

↑

← →

↓ On turns on the machine key

Red LED: SSM and door control communication failure

Green LED: SSM and door control communication is normal

0----9 number button

Esc returns to the previous menu

Enic input confirmation button

↑

← → Menu arrow keys are used to adjust

↓ Menu parameters

← Close button

→ Open the door

main menu

Status door movement control and current status display of the door

↓ ↑

Inspec stepper moving door (in millimeters)

↓ ↑

Set close pos set the door closed position

↓ ↑

Set open pos set the door open position

↓ ↑

Set close speed Set the door closing speed

↓ ↑

Set open speed

↓ ↑

Set close force

↓ ↑

SPECIAL

FUNCTIONS enters the "Special Features" menu

↓ ↑

CONTROL Select control mode (elevator or SSM) 0=lift 1=ssm

Press ESC to return to the first level menu (status)

Special function menu

SPECIAL FUNCTIONS Press → motor rotation

↓ ↑ Motor rotation direction

Encoder phases

↓ ↑

SET Lockg dist

↓ ↑Set the locking distance

Cls lckg speed

↓ ↑Set the locking speed

Opg lckg speed

↓ ↑ set the unlock speed

Set drive para NO=(1022)mm ←

→ Set drive para

↓ ↑ Set the number of encoder pulses

Error code ←

→ Statistics

↓ 出错 Error code ↓ ↑ Statistics menu

Opening detec Set deceleration

↓ ↑ Number of open doors ↑ Set deceleration

Obstade detec Set acceleration

Set the number of times to set the acceleration

Deceleration and acceleration are equally effective for opening and closing doors

Press ESC to return to SPECIAL FUNCTIONS

Initialization start

Initial startup phase needs to perform initialization startup

First confirm all the initial menus (see steps 5-9), then the menu status closed must appear, if not, all steps must be repeated.

1; Set the service switch to the inspection position.

2; open ssm, display

3 keep ssm in its infrared cone receiving range,

The green light should be on ssm

4 wait until inspec; cloed. Or stopped mode appears, press ↓

5 Confirm the door closed position; lust vf1204→, x=(2)

Hanning ccl 1100→x=(0)

Display button

6 Confirm the door open position

X=BKE is used to open the door

X=BKE/2 is used for splitting the door

7 Confirm the door closing speed

Press ↓

8 Confirm the door opening speed

Press ↓

9 Confirm the door closing force

Press ↓

10 complete initialization start

(If not as shown, please repeat the above steps)

11 Exit the inspection mode

Second; diagnosis

1 Select: “Special Features” button on the menu

2 Select the “Statistics” menu and press ↑↑

3 Select the “Error Code” menu and press ↑↑

Code failure description error correction

1 The system is not in operation. The main switch is not reset.

2 The maximum permissible torque exceeds the parameter too low

3 Low voltage check main power supply voltage

4 The voltage is too high Check the main power supply voltage

5 Inverter temperature is too high Check temperature sensor connection

6 Motor temperature is too high Check temperature sensor connection

7 Open circuit check all connections (main power and motor)

8 Internal system problem The main switch is not reset

9 Motor overload check drive parameters and ventilation

10 parameter range check parameter input range

13 Position error check encoder connection and open position value

14 Configuration Error Check Drive System / EEPROM

15 communication error check drive system

17 power supply error check power supply

20 encoder error check encoder connection

Steel Light Pole

Yixing Futao Metal Structural Unit Co. Ltd. is com manded of Jiangsu Futao Group.
It is located in the beach of scenic and rich Taihu Yixing with good transport service.
The company is well equipped with advanced manufacturing facilities.
We own a large-sized numerical control hydraulic pressure folding machine with once folding length 16,000mm and the thickness 2-25mm.
We also equipped with a series of numerical control conveyor systems of flattening, cutting, folding and auto-welding, we could manufacture all kinds of steel poles and steel towers.
Our main products: high & medium mast lighting, road lighting, power poles, sight lamps, courtyard lamps, lawn lamps, traffic signal poles, monitor poles, microwave communication poles, etc. Our manufacturing process has been ISO9001 certified and we were honored with the title of the AAA grade certificate of goodwill.
Presently 95% of our products are far exported to Europe, America, Middle East, and Southeast Asia, and have enjoyed great reputation from our customers.
So we know the demand of different countries and different customers.
We are greatly honored to invite you to visit our factory and cheerfully look forward to cooperating with you.

Steel Light Pole,Steel Street Light Poles,Stainless Steel Light Poles

YIXING FUTAO METAL STRUCTURAL UNIT CO.,LTD( YIXING HONGSHENGYUAN ELECTRIC POWER FACILITIES CO.,LTD.) , https://www.chinasteelpole.com