Inverter technical description:
Low-range machine, input, main voltage 230V+15%/--20% 47-63Hz
115V+15%/--20% 47-63Hz
Output, rated power, 380W (6-pole motor)
Power frequency, greater than >90%
Pulse frequency, ≥16KHz
Output voltage 3. 0---230V
Rated current, 2A
Rotating magnetic field frequency, 0---400Hz
Protection type, ZP20
High-end machine, input, main voltage 230V+15%/--20% 47-63Hz
115V+15%/--20% 47-63Hz
Output, rated power, 600W (6-pole motor)
Power frequency, greater than >90%
Pulse frequency, ≥16KHz
Output voltage 3. 0---230V
Rated current, 3.5A
Rotating magnetic field frequency, 0---400Hz
Protection type, ZP20
SSM Overview
display
On ¤ ¤
1 2 3
4 5 6
7 8 9
Esc 0 Enic
↑
↠→
↓ On turns on the machine key
Red LED: SSM and door control communication failure
Green LED: SSM and door control communication is normal
0----9 number button
Esc returns to the previous menu
Enic input confirmation button
↑
↠→ Menu arrow keys are used to adjust
↓ Menu parameters
↠Close button
→ Open the door
main menu
Status door movement control and current status display of the door
↓ ↑
Inspec stepper moving door (in millimeters)
↓ ↑
Set close pos set the door closed position
↓ ↑
Set open pos set the door open position
↓ ↑
Set close speed Set the door closing speed
↓ ↑
Set open speed
↓ ↑
Set close force
↓ ↑
SPECIAL
FUNCTIONS enters the "Special Features" menu
↓ ↑
CONTROL Select control mode (elevator or SSM) 0=lift 1=ssm
Press ESC to return to the first level menu (status)
Special function menu
SPECIAL FUNCTIONS Press → motor rotation
↓ ↑ Motor rotation direction
Encoder phases
↓ ↑
SET Lockg dist
↓ ↑Set the locking distance
Cls lckg speed
↓ ↑Set the locking speed
Opg lckg speed
↓ ↑ set the unlock speed
Set drive para NO=(1022)mm â†
→ Set drive para
↓ ↑ Set the number of encoder pulses
Error code â†
→ Statistics
↓ 出错 Error code ↓ ↑ Statistics menu
Opening detec Set deceleration
↓ ↑ Number of open doors ↑ Set deceleration
Obstade detec Set acceleration
Set the number of times to set the acceleration
Deceleration and acceleration are equally effective for opening and closing doors
Press ESC to return to SPECIAL FUNCTIONS
Initialization start
Initial startup phase needs to perform initialization startup
First confirm all the initial menus (see steps 5-9), then the menu status closed must appear, if not, all steps must be repeated.
1; Set the service switch to the inspection position.
2; open ssm, display
3 keep ssm in its infrared cone receiving range,
The green light should be on ssm
4 wait until inspec; cloed. Or stopped mode appears, press ↓
5 Confirm the door closed position; lust vf1204→, x=(2)
Hanning ccl 1100→x=(0)
Display button
6 Confirm the door open position
X=BKE is used to open the door
X=BKE/2 is used for splitting the door
7 Confirm the door closing speed
Press ↓
8 Confirm the door opening speed
Press ↓
9 Confirm the door closing force
Press ↓
10 complete initialization start
(If not as shown, please repeat the above steps)
11 Exit the inspection mode
Second; diagnosis
1 Select: “Special Features†button on the menu
2 Select the “Statistics†menu and press ↑↑
3 Select the “Error Code†menu and press ↑↑
Code failure description error correction
1 The system is not in operation. The main switch is not reset.
2 The maximum permissible torque exceeds the parameter too low
3 Low voltage check main power supply voltage
4 The voltage is too high Check the main power supply voltage
5 Inverter temperature is too high Check temperature sensor connection
6 Motor temperature is too high Check temperature sensor connection
7 Open circuit check all connections (main power and motor)
8 Internal system problem The main switch is not reset
9 Motor overload check drive parameters and ventilation
10 parameter range check parameter input range
13 Position error check encoder connection and open position value
14 Configuration Error Check Drive System / EEPROM
15 communication error check drive system
17 power supply error check power supply
20 encoder error check encoder connection
Steel Light Pole,Steel Street Light Poles,Stainless Steel Light Poles