Liquor analysis internal standard method
Preparation of the sample to be tested: (internal standard generally refers to: n-butyl acetate), purchased as
5ml
Chromatographically pure n-butyl acetate.Liquor internal standard preparation steps:
(
1
)60%
Ethanol preparation: take150ml
Anhydrous ethanol (usually chromatographically pure) is made up to volume with purified water250ml
.(
2
)2%
Internal standard preparation: take5ml
N-butyl acetate60%
Condensate ethanol to250ml
.(
3
) with sample wine sample preparation: take10ml
Sample to be tested plus0.2ml
of2%
The internal standard, at this time the internal standard concentration in the wine sample is:35.28mg/100ml
.use
10ul
Microsampler1ul
The wine sample to be tested can be.Note: With wine sample preparation: Take
10ml
Sample to be tested plus0.2ml
of2%
Internal standard, the wine sample at this timeThe internal standard concentration is:
35.28mg/100ml*2==0.56 mg/100ml
.The liquor mixed standard is calculated by the instrument to calculate the correction factor:
N2000
Chromatography workstation as an example)Liquor analysis internal standard method operation steps:
1.
Advanced liquor mixed standard
1ul
Standard online workstation, sample records and save the name, for example, a white wine standardA
.(Note that the first needle is generally not used, it is best to use the second needle.)
2.
Processing in an offline workstation, open → liquor standard
A
→OK→No→Map→Integration Method→Area→InsideMark → drift set
400
→ Use → Spectral → If the spectrum baseline is not good, you need to manually process the baseline → component table → select all → enter the peak name according to the peak time → select the component table before the internal standard peak (white wine is n-butyl acetate peak) Press and hold the mouse, left button is not raised to the first row of the component table → double click on the internal standard peak, change to → calibration → standard content → fill in the component content according to the content table of the mixed label →OK
→Add standard samples→Select liquor standardA
→ OK → Correction → Output → Input method file name, for example: liquor calibration curveA
→Save.3.
In the online workstation when analyzing the liquor sample: Open → liquor calibration curve
A
→ Open → Method → ​​Component Table → The internal standard concentration of the internal standard is filled into the internal standard concentration of the wine sample → use.4.
Entering the wine sample with the internal standard
1ul,
Collect data, stop, save, and click preview.5.
If the peak is not identified, the retention time in the component table should be changed to the current time offline → Adopt → Output
Aluminum Frame LV 3PH Asynchronous Motor
Aluminum Frame Lv 3Ph Asynchronous Motor,Three-Phase Asynchronous Motor,3 Phase Asynchronous Induction Motor,Aluminum Frame Three Induction Motor
Yizheng Beide Material Co., Ltd. , https://www.beidevendor.com