Metal-clad ac switchgear
1.Service condition
- Altitude:<=1000m
- Ambient air temperature:-10ºc to +40ºc
- Ambient humidity:Daily average humidity <=95%
- Monthly average humidity<=90%
- Earthquake intensity<=magnitude 8
- Without corrosive, flammable gas and steam and no regular severe shock
- For special service condition, need to negotiable with manufacture
2.     StructureÂ
2.1 Enclosure
Switchgear enclosure adopts imported aluminum zinc steel sheet by CNC machine tool processing, and use multi-fold workmanship strong oxidation resistance and corrosion resistance, light weight, strong mechanism strength.
Enclosure with degree of protection IP4X is divided into four separated compartments, when the door opens the compartment and circuit breakers the degree of protection is IP2X
2.2 Trolley(VCB)
The trolley frame assembled with thin steer after CNC machine tool. The trolley co-ordinated with the switchgear as to make the mechanical interlock safe and reliable. Trolley with the same specification are interchangeable.
Circuit breaker trolley is equipped with vacuum circuit breaker and other auxiliary equipment, the VCB can be circuit VD4 of ABB or VT19 manufactured by ourselves. It can be reliably locked in disconnected position, test position to ensure reliable interlock.
2.3 Busbar component
The branch bus is connected to the static contact box and main busbar without other supports. Main busbar is separated and fixed by the bushing in case of arc failure.
This construction can effectively prevent the accident spreading to other cabinets.
2.4 Instrument cabinet
All kinds of switch, status-indicator and measuring instrument etc could be mounted on the door of the instrument. Protective relay, secondary wire, terminal and air switch, low-voltage fuses, etc, are equipped inside the instrument cabinet.
2.5 Fail- safe interlock
There is a "anti-5" mechanical latch between the disconnector, VCB and panel door, a reliable measurement to prevent from mis-operation, convenient and safe maintenance, flexible operation.
3.     External Dimension And Weight
 12k
Height H(mm) Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 2300(2200) | ||
Width w(mm) |
Rated current of branch busbar is up to 1250A Short time withstand current is 40KA |
800 |
Rated current of branch busbar is up to 1600A and above | 1000 | |
Depth d(mm) | Cable incoming and outgoing | 1500 |
Overhead incoming and outgoing feeder | 1660 | |
Weight(kg) Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 700-1200 |
Â
Â
Network power supply, it is 12V DC power supply, With reliable iron shell for better heat radiation, power supply network stable designed circuit with wide voltage input & accurate stabilivolt
Features:
Using pure cooper wire,and 100% enough power output.
With reliable iron shell for better heat radiation;
Stable designed circuit with wide-voltage input & accurate stabilivolt;
Multi-protection against short circuit, over current, overload, ;
With 100% over-loading aging test guaranteed;
High efficiency, long life and great stability;
With exquisite appearance ,portable use & easy maintenance.
Product application:
Application to CCTV camera,access control,door control system.
Network Power Supply
Network Power Supply,Network Switch Power Supply,Network Controlled Power Supply,Network Backup Power Supply
Dongguan Xiaoerduo Electronics Co., Ltd. , http://www.steadysmps.com